Ia4100, Administrator guide, Programming commands (continued) – Code Blue IA4100 SINGLE BUTTON ANALOG SPEAKERPHONE User Manual
Page 21

Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-139-J
page 21 of 29
IA4100
Administrator Guide
Programming Commands (continued)
Programming Hang Up Methods
Command
Explanation
Format
Default
40
Polarity Reversal/WINK
40
2#
41
Revert back to dial tone
41
00#
42
Silent time out
42
0#
43
Repeating (reorder) tone 43
00#
44
Call time out
44
10#
45
WINK Voltage Minimum
45
0#
46
Minimum Ring Voltage
Detection
46<0, 1 or 2>#
0#
47
Maximum Ring
Frequency
47<0, 1 or 2>#
0#
NOTES: FORMAT VALUE PARAMETERS
Command 40 = WINK time: 0 - 9
0 = disabled
1 - 9 = 100 - 900 milliseconds
Command 41 = Length of dial tone: 00 - 99
00 = disabled
01 - 99 = 1 - 99 seconds
Continuous sound for this period will initiate hang up
Command 42 = Silent time out: 0 - 9
0 = disabled
1 to 9 (10 to 90 in 10-second increments)
Command 43 = Number of repeating tones: 00 - 99
00 = disabled
01 - 99 = 1 - 99 cycles
Command 44 = Call time out timer: 00 - 99
00 = disabled
01 - 99 = minutes
A DTMF “BBBBB” notifier plays to both parties 30 seconds prior to expiration
Command 45 = Minimum “voltage change” to interpret as a “WINK”
0 = 5V thru 9 = 14V
Command 46 = Minimum Ring Voltage Detection Threshold measured in Vrms
0 = 13, 1 = 19
2 = 40
Command 47 = Maximum Ring Frequency measured in Hz
0 = 75, 1 = 50, 2 = 35
(Continued on next page)