beautypg.com

Ia4100, Administrator guide, 1 initial in-call commands – Code Blue IA4100 SINGLE BUTTON ANALOG SPEAKERPHONE User Manual

Page 15

background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-139-J

page 15 of 29

IA4100

Administrator Guide

12.1 Initial In-Call Commands

The following commands are used after the RFA (Request For Acknowledgement) tone upon initial

call in. When calling the extension or phone number of the IA4100 you will hear the RFA tone

(DTMF “B”). If a new command mode is not selected within seven seconds, the IA4100 will default

to two-way call mode (full monitoring) and will start accepting “Commands During A Call” (see

page 8).

Initial Call-In Modes

Command

Explanation

Format

Default

1

Programming Mode

1 #

1 2583#

3

Full Monitoring, two-way

(microphone and speaker)

3 #

3#

4

Silent Monitoring, one-way call

(speaker is off)

4 #

4#

5

Monitoring, one-way call

(microphone is off)

5 #

5#

8

UPD Fault Reporting Mode

1

8#

9

Paging Mode

2

9#

Ý

#

Forced Hang Up

Ý

#

NOTES:

1

UPD Fault Reporting Mode allows the UPD software to check the system for faults.

2

Paging Mode is utilized to send the incoming call output to the attached Public Address

System (PAS) amplifier/speaker array.