CB 5 Series
Administrator Guide
15 CB 5-s with Public Address Installation Instructions
Code Blue CB 5 Bollard
5
4
2
1
Lexan Dome Top w/ Active Vent
Public Address System (PAS) unit
Amplifier
Hex Head Screws & Washers
PAS Adapter Ring
Gasket
7
6
2
1
To 24V AC
on Manifold
To Aux Output on
Phone Board
3
TOOLS REQUIRED
1.0 INSTALL ADAPTER RING
1.1 Place PAS Adapter Ring on gasket of the CB 5 unit
and rotate to align with the three pre-drilled holes.
1.2 Apply Loctite
®
or a protective sealant on screw
threads.
1.3 Attach Adapter Ring to the bollard using three 3/8”-
16 hex head screws and washers provided.
2.0 INSTALL AMPLIFIER
2.1 Connect Yellow/Yellow wire harness from the bea-
con/strobe mounted in the PAS unit to the Aux Output
on the phone board with the provided Yellow/Yellow
extension harness.
2.2 Connect the Red/Black wire harness from the bea-
con/strobe mounted in the PAS unit to the Red/Black
24V AC connector on the manifold connected to the
transformer with the provided Red/Black extension
harness.
2.3 The 2-pin connector from the speaker should be
connected to the amplifier. Verify that this connection
is secure after shipment.
2.4 On the provided wiring harness, connect the Green
ground wire with an eyelet to the stud on the amplifier
box with the provided #6-32 nut with star washer.
2.5 On the provided wiring harness connect the two
6-pin White connectors to the amp box and to the
transformer.
2.6 With the cable provided, connect the PAS Audio on
the amp box and the Audio Output on the phone
board via the RJ-11 connectors.
2.7 With the cable provided, connect the 8-pin PAS
Control on the amp box and the 8-pin PAS Control
on the phone board.
3.0 INSTALL PAS SPEAKER UNIT
3.1 After all of the connections are made, mount the PAS
unit onto the PAS Adapter Ring. Rotate to align the
six holes and secure with the provided six #10-24
countersunk security screws.
4.0 SEE GUIDE FOR BEACON/STROBE INSTALL
NOTE: 120V AC must be supplied to the unit.
NOTE: If an Overhead Camera Mount and/or IP
Wireless Ring is also being installed, place on bol-
lard BEFORE PAS Adapter Ring.
Phillips
Screwdriver
Ladder
Access Panel
Security Bit
¼” Allen
Wrench
Hex Head
Wrench