Technical specifications – Cloud Electronics 46-50 - CXL-4160 User Manual
Page 6

CXL-4160 Installation Instructions v1.0
6
SAFETY NOTES REGARDING INSTALLATION
The CXL-4160 is an accessory for the Cloud 46-50, and when installed in this product, conforms to the relevant European
Electrical Safety and EMC Standards.
The CXL-4160 is specifically designed to be fitted internally in the 46-50. Should the CXL-4160 be mounted in any other
enclosure, the enclosure must be electrically safe and meet the requirements of BS EN 60065.
THE INSTALLATION OF THE CXL-4160 IS BEYOND THE CONTROL OF
CLOUD ELECTRONICS LTD., AND WE ACCEPT NO RESPONSIBILITY FOR
HAZARDOUS INSTALLATIONS.
TECHNICAL SPECIFICATIONS
CXL-4160; EACH TRANSFORMER
Maximum input voltage
16 Vrms
Input impedance
4 ohms (with 250 ohm secondary load)
Output power rating
40 W
Minimum load impedance
250 ohms
Distortion
<0.03% @1 kHz