TECHNICAL CHARACTERISTIC TABLES
NORMAL
NOMINAL
INJECTOR
TAP
NOMINAL
HEAT
BURNERS
GAS
PRESSURE RATE
DIAMETER BY PASS INPUT
DIAMETER (WATT)
N° Description
Mbar
g/h L/h 1/100 mm 1/100 mm Max. Min.
G30
30
218
-
85
40
3000 900
1 RAPID
G31
37
214
-
85
40
3000 900
G20
20
-
274
128
Reg.
3000 900
G30
30
120
-
65
29
1650 600
2 SEMI-RAPID
G31
37
118
-
65
29
1650 600
G20
20
-
154
94
Reg.
1650 600
G30
30
73
-
50
27
1000 450
3 AUXILIARY
G31
37
72
-
50
27
1000 450
G20
20
-
95
76
Reg.
1000 450
G30
30
240
-
92
60
3300 1850
4 ULTRA-RAPID
G31
37
236
-
92
60
3300 1850
G20
20
-
312
139
Reg.
3300 1850
DESCRIPTION
A – B
D
C
E
F
G
(page 4)
GAS RATES
531 g/h
7,3 kW
553 g/h
7,6 kW
604 g/h
8,3 kW
240 g/h
3,3 kW
291 g/h
4 kW
411 g/h
5,65 kW
VOLTAGE
230 V
50 Hz
230 V
50 Hz
230 V
50 Hz
230 V
50 Hz
230 V
50 Hz
230 V
50 Hz
POWER
_
_
_
_
_
1500 W
RATING