Fastening the top
Every cook-top is equipped with a special gasket having an adhesive side.
• Remove the racks and burners from the top.
• Turn the appliance upside down and lay the adhesive washer S along the external
border of the glass (fig.5).
• Introduce and place the cook-top in the hole made in the piece of furniture, then block it
with the V screws of the fastening hooks G (fig.6).
Installation room
This appliance is not provided with a device for exhausting the products of combustion,
therefore, it is necessary to discharge the fumes outside. The room where this appliance is
installed must have a natural air inflow, so as to ensure a regular gas combustion and room
ventilation: the necessary air volume must not be lower than 20 m3.
Air must come from permanent openings made on the room walls that communicate with
the outside.
The section of these openings shall correspond to at least 200 cm2.
Gas connection
Make sure that the appliance is adjusted for the gas type available (see the label under the
appliance). Follow the instructions indicated in the chapter "gas transformations and
adjustments" for the possible adaptation to different gases. The appliance must be
connected to the gas system by means of stiff metal pipes or flexible steel pipes having
continuous walls, in compliance with the regulations in force.
Gas enters the appliance through a cylindrical threaded male gas union (1/2").
The connection must not stress the gas ramp.
Once the installation is over, check the connection seal with a soapy solution.
Electric connection
The connection to the electric grid must be carried out by qualified personnel and in
conformity with the regulations in force.
The voltage of the electric system must correspond to the value indicated in the label under
the appliance. Make sure that the electric system is provided with an effective ground
connection in compliance with the regulations and provisions of the law. Grounding is
compulsory. If the appliance is not equipped with a plug, apply a standardised plug to the
power supply cable.
It is possible to effect the connection to the electric grid directly, by interposing an omni
polar switch having a contact opening distance of at least 3 mm.