BUG-O Systems SE-4PTD User Manual
Page 20

20
Type 5.
Functions or other operations.
Quadrant by selection function. (See chart)
1. Weld/ oxygen ON: turn ON contact Relay or cutting oxygen solenoid.
 Dimensions required: none
2. Weld/ oxygen OFF
 Dimensions required : None
3. Pause: machine stops and waits until Start/ Run button is pushed again.
 Dimensions required: None
4. Delay: Machine stops and hold position for a programmed time period, up to 99.99
 Seconds.
 Dimensions required: time in .01 seconds units. (e.g. 250 for 2.5 seconds)
Type 6.
Special functions.
Quadrant by selecting function.
1. Repeat: Another complete shape will be repeated the specified number of times.
 Shape No. of the repeated shape MUST BE LOWER than the Shape No. of the
 current shape being programmed. Therefore it CANNOT BE USED IN
 SHAPE No. 0
 Data required: (1) Shape No. to be repeated
(2) Number of times.
2. Ellipse: This is provided for making a complete true ellipse, always starting from
 the left (west extremity) and moving clockwise.
 Dimension required: (1) diameter along X- axis
(2) diameter along Y- axis
 3. Auxiliary modes: Provides commands to turn On or OFF two line-switching
 outputs independently, and also switch speeds from set speed to Rapid Traverse
 and back. Mode numbers are from 0 to 7; see table page 36 to select mode.
4. Set percent speed
 Used to change speed of the machine in the middle of a shape to a lower speed. See details
 page 22.
Type 7.
Clockwise arc, must be less than 180°.
Quadrant determined by direction of end point of arc relative to the start point. (See chart)
Dimensions required:
(1) X- dimensions: offset along X-axis from start to end point
(2) Y-dimensions: offset Y- axis from start to end point
(3) Radius of arc.