BUG-O Systems SE-4PTD User Manual
Page 19
19
DATA ENTRY required for Programming
To Program a complete new shape (press ‘A’)
Count the number of segments or operations and enter the total.
For each segment, enter:
Type:
Select form 1 through 8
Quadrant:
1, 2, 3 or 4; refer to chart
Size:
one or more dimensions per segment as described below
100 per inch or 10 per mm (depending on machine version); or for
time, 100 per second of delay.
(e.g. 150 = 1.5”, or for metric 375 = 37.5 mm)
Detailed description of Types
Type 1.
Clockwise, 90° arc segments.
Quadrant determined by which quarter of a full circle makes the arc. (See chart)
Dimensions required: Radius only.
Type 2.
Counterclockwise, 90° arc segments
Quadrant determined by which quarter of a full circle makes the arc. (See chart)
Dimensions required: Radius only.
Type 3.
Lines along X or Y axis.
Quadrant determined by direction of movement. (See chart)
(East: 1, North: 2, West: 3, South: 4).
Dimensions required: Length only.
Type 4.
Angled straight line.
Quadrant determined by direction of movement. (See chart)
(NE: 1, NW: 2, SW: 3, SE: 4).
Dimensions required: (1) X- dimension; movement along X axis
(2) Y- dimension; movement along Y axis