beautypg.com

Factory settings, Change the display language 9, 0 factory settings – Bluelab pH Controller Connect Manual User Manual

Page 9: 0 change the display language

background image

English

9

12.0 Factory settings

The pH controller connect is set to the following values by default:

Note: ‘Pump runtime’ [HH:MM:SS] is the time the pump has dosed for. ‘Product

runtime’ [Hrs] is the duration of time the pH controller connect has been in use for.

Pump runtime and product runtime are never reset, even after pump replacement.

To restore the pH controller connect to the above factory settings at any stage:
• Disconnect the power
• Press and hold the ‘cal’ button then reconnect the power.
• When ‘Restored Factory Defaults’ is displayed on the screen, release the ‘cal

button’.

1

2

• Mode

Monitor

• Set

pH

5.8

• Alarm

On

• HighAlarm

6.5

• LowAlarm

5.6

• Dose

Up/Dn

Down/Acid

• OnTime

1Sec

• OffTime

10Min

• Backlight

100%

On

• Contrast

16

• 2/3pt

Cal

2

• EarthLink

Off

• Language

eng

• pH

Calibration none

13.0 Change the display language

Press ‘menu’. Press ‘

’ to fi nd language. Press

‘enter’ to select.

Press ‘

’ or ‘’ to fi nd the required language.

Press ‘enter’ to save the language selection.

Press ‘menu’ to exit the menu.

1

2

3

This manual is related to the following products: