Prepare measurement – Beurer BM 19 User Manual
Page 17
17
4. Prepare measurement
Inserting battery
• Remove the battery cover from
the back of the monitor.
• Insert four AA 1.5 V alkaline
batteries. making absolutely
sure that you insert them with
the correct polarity as marked.
Never use rechargeable bat
teries.
• Replace the battery cover carefully.
If the battery change
is continuously illuminated,
measure ment is no longer possible and you must replace all
the batteries. Once batteries have been removed from the
device, the time must be reset. The stored measured values
are last.
Used batteries do not belong in the household waste. You are
legally obliged to dispose of the batteries. Dispose of them via
your specialist electrical supplier or local collec ting point for
recyclable waste.
Note: Batteries containing pollutant substances
are marked as follows: Pb = Battery contains
lead, Cd = Battery contains cadmium, Hg = Bat
tery contains mercury.
Setting date, time and language
It is vital to set the date and time. This is the only way that measure
ments can be saved and recalled with the correct date and time.
The time is shown in 24 hour format. The device also has five
languages. The device is set to German on delivery.
Proceed as follows to set the date, time and language:
• Press the memory button M for over 5 seconds.
• The day starts flashing. Use the +/- key to set the day from 1
to 31 and confirm with the memory button M.
• Set the month, hour and minute and confirm in each case
with the memory button M.
• After setting the date and time you can set the language.
• Use the + and - volume keys to select the following lan
guages: L1 = German, L2 = Italian, L3 = French, L4 = Span
ish, L5 = Russian, L0 = no language. Confirm your selection
with the memory button M.
• You can then set the volume of the selected language:
Vol 3 = high, Vol 2 = medium, Vol 1 = low. Confirm your
selection with the memory button M.
Note: Language off (L0) means that voice output is not
selected and the measurement value will not be announced.
Operation with the mains part
You can also operate this device with a mains part.
When doing so, there must not be any batteries in the battery
compartment. The mains part can be obtained from special
ist retailers or from the service address using order number
071.13.
• To prevent possible damage to the device, the blood pres
sure monitor must only be used with the mains part descri
bed here.
• Insert the mains part into the connection provided for this
purpose on the righthand side of the blood pressure moni
tor. The mains part must only be connected to the mains vol
tage that is specified on the type plate.
4x 1,5 V AA (LR6)