Water system setup procedure, Water regulator set up – Belshaw Adamatic Harmony Deck Oven User Manual
Page 14
![background image](https://www.manualsdir.com/files/775250/content/doc014.png)
WATER SYSTEM SETUP PROCEDURE
It is imperative that the water delivery to the deck oven is checked for the
steam system to operate correctly
1. Flush out the main feed pipe to be used, until water runs clear and free from debris.
2. Connect main feed to oven.
3. Connect flexible hoses to each deck.
4. Place a container under the test valve.
5. Slowly open test valve fully and with the water flowing check the regulator is set to
0.75 bar. If not adjust using the screw above the valve.
x Never use the oven above this setting
6. When the pressure has stabilised shut the test valve.
REPEAT 4,5 AND 6 AT THE END OF INSTALLATION.
NOTE. DYNAMIC PRESSURE, NOT STATIC, IS BEING MEASURED.
FG257 MODULAR DECK 02/07 RAC
13
STOP TAP
ADJUSTING SCREW
SET TO 0.75 bar
TEST VALVE
FILTER
TO OVENS
FROM SUPPLY
CHECK VALVE
RESTRICTOR
WATER REGULATOR SET UP
LOCATED ON REAR OF OVEN
REGULATOR