4 electrical components, Testing the continuity of a toggle switch – Belshaw Adamatic FT42 Feed Table User Manual
Page 21
Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
Feed Table FT42 TS
MN-1668EN
7
4 Electrical
Components
This section explains how to test the continuity
of electrical components in the FT42-E Feed
Table.
Testing the Continuity of a
Toggle Switch
WARNING
To avoid the possibility of electric shock,
disconnect the machine from the power
source before testing.
1. Disconnect the machine from the power
source.
2. Disconnect the terminal wires from the
switch.
3. Obtain a continuity tester or a volt-ohm
meter. If neither of these instruments is
available, make a continuity tester using a
battery and a bulb. (See Figure 4-1.)
4. Connect the wires of the continuity tester to
the switch terminals, as shown in Figure 4-1,
and test the switch in the ON and OFF
positions. The switch should show
continuity only when in the ON position.
Figure 4-1. Toggle Switch Continuity Test.
+