background image

C1120 S5 to II/O-Lightbus Interface

Beckhoff II/O-Lightbus System

Page 22 of 52

Version 2.1

Date 27.06.97

Online Menu

For transfer of setups from a PC to the C1120 interface and back, the online menu helps to
control communication actions, saving and printing of project setups:

If a communication timeout occurs during or at start of a transfer, first action to be taken
should be to check the RS232 interface cable and the serial interface parameters in the menu
"Program Parameters".

Function keys:

F1

HELP

displays help text.

F2

RESET C1120

Generates a software reset of the C1120 interface. The interface boots and runs
through following steps:

-

self test of the C1120 interface,

-

the configuration saved in the EEPROM memory is loaded and activated,

-

the II/O-Lightbus ring is reset.

The status of the C1120 is displayed after completion of the reset in the status