background image

Status information


Display after the replacement of a defective hard disk

Without rebuilding the RAID
volume

If the defective hard disk was exchanged (please refer to chapter

Requirements for a replacement hard disk

) whilst the Industrial PC was

switched off, or if the hard disk was exchanged under Windows during
operation without starting a rebuild of the RAID volume, the second boot
screen will appear as follows at the next PC start-up:

Boot screen

A hard disk is shown on Port 1 that does not belong to any RAID volume.
The new hard disk can be selected in the Configuration Utility for the
rebuild of the RAID volume (see chapter

Selecting a hard disk for the RAID

rebuild

).

However, it is also possible, without first opening the Configuration Utility,
to boot Windows, where the hard disk can then also be selected for the
rebuild of the RAID volume (see chapter

Selecting a hard disk (drive) for

the RAID

rebuild).

Beckhoff onboard SATA-RAID