3.17 Serial Ports COM2 through COM4

There are three more serial interfaces on the board. Of these, COM3 is available through the power
connector (cf. p. 16). COM2 and COM4 and made available via a 2x5 pin connector each (JST
B10B-PHDSSLFSN, mating connector: PHDR-10VS). However, if the board has a touch screen interface,
COM4 is used internally. On these boards, the COM4 connector is either not populated or it is used for
mouse and keyboard signals (see pinning below). Signals default to RS232 level but can be ordered as
TTL level also.
The port address and the interrupt are set via the BIOS setup.


Description

Name

Pin

Name

Description

data carrier detect

DCD

1

6

DSR

data set ready

receive data

RXD

2

7

RTS

request to send

transmit data

TXD

3

8

CTS

clear to send

data terminal ready

DTR

4

9

RI

ring indicator

ground

GND

5

10

VCC

5 volt supply

Alternative pinout of COM-connector when touchscreen feature is present:

Description

Name

Pin

Name

Description

keyboard clock

KCLK

1

6

MCLK

mouse clock

keyboard data

KDAT

2

7

MDAT

mouse data

reserved

N/C

3

8

N/C

reserved

reserved

N/C

4

9

N/C

reserved

ground

GND

5

10

VCC

5 volt supply