beautypg.com

16 serial interface com1 – BECKHOFF CB3052 User Manual

Page 32

background image

Chapter: Connectors

Serial Interface COM1

page 32

Beckhoff New Automation Technology CB3052

3.16 Serial Interface COM1

The serial interface COM1 is made available via a 9-pin standard DSUB-connector. According to the
product order, TTL level signals or RS232 standard signals are provided.

The port address and the interrupt are set via the BIOS setup.

Pinout serial port (DSUB connector):

Description

Name

Pin

Name

Description

data carrier detect

DCD

1

6

DSR

data set ready

receive data

RXD

2

7

RTS

request to send

transmit data

TXD

3

8

CTS

clear to send

data terminal ready

DTR

4

9

RI

ring indicator

ground

GND

5