3.4.5 PCI interfaces
There are three standard PCI slots available on the CB1061.
N
OTE
Please note that due to the nature of the PCI bus some signals in the following table are different from
one PCI slot to the other. This applies to the test signals (A4, B4), the interrupt signals (A6, A7, B7, B8),
the clock signal (B16), the grant signal (A17), the request signal (B18), and the ID-select signal (A26).
Pinout PCI slot:
Description
Name
Pin
Name
Description
test logic reset
TRST#
A1
B1
-12V
-12 volt supply
12 volt supply
12V
A2
B2
TCK
test clock
test mde select
TMS
A3
B3
GND
ground
test data input
TDI
A4
B4
TDO
test data output
5 volt supply
VCC
A5
B5
VCC
5 volt supply
interrupt A
INTA#
A6
B6
VCC
5 volt supply
interrupt C
INTC#
A7
B7
INTB#
interrupt B
5 volt supply
VCC
A8
B8
INTD#
interrupt D
reserved
N/C
A9
B9
GND
ground
5 volt supply
VCC
A10
B10
N/C
reserved
reserved
N/C
A11
B11
GND
ground
ground
GND
A12
B12
GND
ground
ground
GND
A13
B13
GND
ground
3.3 volt supply
3.3VAux
A14
B14
N/C
reserved
PCI reset
PRST#
A15
B15
GND
ground
5 volt supply
VCC
A16
B16
PCLK
clock
grant PCI use
GNT#
A17
B17
GND
ground
ground
GND
A18
B18
REQ#
request
power management event
PME#
A19
B19
VCC
5 volt supply
address/data 30
AD30
A20
B20
AD31
address/data 31
3.3 volt supply
3.3V
A21
B21
AD29
address/data 29
address/data 28
AD28
A22
B22
GND
ground
address/data 26
AD26
A23
B23
AD27
address/data 27
ground
GND
A24
B24
AD25
address/data 25