7 general overview (ax5192 and ax5193) – BECKHOFF AX5000 60 A - 170 A User Manual
Page 21

BECKHOFF
Drive Technology
4 Product description
AX5000
Version: 1.4
21
4.7
General overview (AX5192 and AX5193)
Item description:
No Designation
No Designation
1 X4x – optional slot for expansion cards
9 X14 – sensor for motor temperature
and brake
2 X3x – optional slot for safety card
10 X07 – External brake resistor
3 X11 – feedback connection, encoder
11 DC link output (890 V DC voltage)
4 X06 – connection for digital inputs and outputs 12 Motor connection (U,V,W,PE)
5 Navigation rocker
13 X04 – socket for EtherCAT input
6 Labeling field
14 Labeling field
7 X05 – socket for EtherCAT output
15 Display
8 X03 – power supply 24 V DC input
16 X12 – feedback connection, resolver
DANGER
Max. 890 V DC voltage at the
DC link terminals. Dangerous
voltage may be present for
45 minutes after the device is
switched off. The device is
safe once the voltage has
fallen below 50 V.
(Check voltage)
17 X01 – mains supply 400 – 480 V