6 general overview (ax5190 and ax5191) – BECKHOFF AX5000 60 A - 170 A User Manual
Page 20

4 Product description
BECKHOFF
Drive Technology
20
Version: 1.4
AX5000
4.6
General overview (AX5190 and AX5191)
Item description:
No Designation
No Designation
1 X4x – optional slot for expansion cards
9 X14 – sensor for motor temperature
and brake
2 X3x – optional slot for safety card
10 DC link output (890 V DC voltage)
Connection for external brake resistor
3 X11 – feedback connection, encoder
11 Motor connection (U,V,W,PE)
4 X06 – connection for digital inputs and outputs 12 X04 – socket for EtherCAT input
5 Navigation rocker
13 Labeling field
6 Labeling field
14 Display
7 X05 – socket for EtherCAT output
15 X12 – feedback connection, resolver
8 X03 – power supply 24 V DC input
16 X01 – mains supply 400 – 480 V
DANGER
Max. 890 V DC voltage at the
DC link terminals. Dangerous
voltage may be present for
30 minutes after the device is
switched off. The device is
safe once the voltage has
fallen below 50 V.
(Check voltage)