Terminal configuration
KL5101
17
Interbus coupler BK4000
By default, the Interbus coupler BK4000 maps the KL5101 with 6 bytes of
input data and 6 bytes of output data.
Offset Klemme 1= 0
Offset Klemme 2 Kanal 1 = 7
The control/ status byte
must be inserted for
parameterization.
The control/ status byte
will be inserted for
parameterization (KL5101).
K-Bus
Interbus bus coupler
BK4000
To the bus terminal
Nutz H
Nutz L
C/S
C/S
D1
D0
D4
(D2)
D3
0
The terminal is
mapped in the
bus coupler
Other bus couplers and
further information
You will find further information on the mapping configuration of bus
couplers in the annex of the respective bus coupler manual and under the
heading of "Configuration of Masters".
Parameterization with the
KS2000 configuration
software
Independently of the field bus system, parameters can be set via the serial
configuration interface in the bus coupler using the Beckhoff KS2000
configuration software.