Appendix, The register of the bus coupler bk5000 – BECKHOFF BK5000 User Manual
Page 10

Appendix
6
BK5000
6
Appendix
The Register of the bus coupler BK5000
Description
Value
range
Default
values
Terminal number
0
Table number
100
Rd/Wr with Software write protection
Register number
0
CAL baud rate
4
Register number
1
CAL Node class
0
Register number
2
CAL Guard time
300
Register number
3
CAL Lifetime
2
Register number
4
Mode of the first eight analogue
terminals
0 :Polling
1 : Cycle
2 : Change of Value
0
4.2*n –
4.2*n+1
Mode n+1 terminal
(n = 0 – 7 )
0, 1, 2,
0
Register number
5 – 12
Mode of digital terminals
0 :Polling
1 : Cycle
2 : Change of Value
0xAAAA
m.2*n –
m.2*n+1
Mode n+1 terminal
(m = 5 – 12; n = 0 – 7 )
0, 1, 2
2
Register number
13
Timer 1 Mode Cycle
0
Register number
14
Timer 2 Mode Cycle
100
Register number
15
Timer 3 Mode Cycle
200
Register number
16
Timer 4 Mode Cycle
300
Register number
17
Assignment of the first 8 analogue
terminals to timer
0 : Timer 1
1 : Timer 2
2 : Timer 3
3 : Timer 4
0
17.2*n –
17.2*n+1
Assingment n+1st terminal
(n = 0 – 7 )
0, 1, 2, 3
0
Register number
18 – 25
Assignment of the digital terminals to
timer
0 : Timer 1
1 : Timer 2
2 : Timer 3
3 : Timer 4
0
m.2*n –
m.2*n+1
Assignment n+1st terminal
(m = 18 – 25; n = 0 – 7 )
0, 1, 2, 3
0
Register number
26
Fieldbus errors
26.15 : CAN BUSOFF (1)
26.14 : CAN ERROR (0)
26.13 : CAN OVERRUN (0)
26.12 : CAN GUARDFAIL (1)
26.11 : CAN NOTOPERATIONAL (0)
26.10 :--
...
26.0 :--
0x9000