Baumatic BHI909TS.GWK User Manual
Page 38

Gas adjustment (Conversion to LPG)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o
Remove the pan-stands, burners and
flame spreaders (A).
o
Unscrew the injector (B) and replace it with
the stipulated injector for the new gas
supply (see the table on the next page).
PRESSURE Ø
INJECTOR
THERMAL
CAPACITY
GAS TYPE
mbar
BURNER
1/100
mm
Nominal W
CONSUMPTION
Natural
gas – G20
20
Triple-
crown
71A-95B
4000
381
l/h
LPG –
G30/G31
28-30/37
Triple-
crown
80A-143B
4000
291
g/h
o
Reassemble all the burners carefully; in particular you should make
sure that the flame spreader is correctly placed on the burner.
o
IMPORTANT: The minimum flow adjustment process must be
completed before the appliance is next used.
38