Baumatic BO610.5SS User Manual
Page 27
Gas adjustment (Conversion to LPG and gas adjustment)
IMPORTANT: Your appliance must be disconnected from the
electric and gas supply before completing this process.
Burner
kW rated load
Ø Nozzle (mm)
G20
20 mbar
G30
50 mbar
G30
29 mbar
Oven
burner 2.50
1.13 0.67 0.76
Grill
burner 2.20
1.12 0.65 0.75
Gas details
Gas Connection Type:
1/2” BSP male thread
Gas Type (Natural Gas G20):
20 mbar
Gas Type (LPG G30/31):
28/37 mbar
Primary air gap (LPG G30/31):
1.0 mm
o
Open the door of the oven.
Unscrew the fixing screws and
then remove the base of the oven
cavity (as shown opposite).
27