beautypg.com

Baumatic BO610.5SS User Manual

Page 24

background image

Gas connection

24

nts.

This appliance must be installed by a competent
person in accordance with the current versions of
the following UK (United Kingdom) or ROI (Republic
of Ireland) Regulations and Safety Standards or
their European Norm Replaceme

Important information

o

This oven is supplied to run on natural gas only and cannot be

used on any other type of gas without modification.

o

Conversion for use on LPG and other gases must only be
undertaken by a qualified person. For information on the use of
other gases, please contact the Baumatic Advice Line.

o

The oven must be installed by a qualified person, in accordance
with the current edition of the Gas Safety (Installation and Use)
Regulations and the relevant building/I.E.E. Regulations.

o

Failure to install the appliance correctly could invalidate
Baumatic’s guarantee and lead to prosecution under the
regulations quoted above.

o

In the UK, only GASSAFE registered installers are authorised to
undertake the installation and service work, in compliance with
the above regulations.

Room ventilation requirements

o

The room containing the oven should have an air supply in
accordance with the current edition of BS 5440: Part 2:

o

The room must have opening windows or equivalent; some
rooms may also require a permanent vent.

o

If the room has a volume between 5 and 10m³, it will require an
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.

o

If the room has a volume of less than 5m³, it will require an air
vent of 100cm² (effective area).

o

If there are any other fuel burning appliances in the same room
the current edition of BS 5440: Part 2: should be consulted to
determine air vent requirements.