Warning – Dukane Ultrasonic Hand Held System iQ Series User Manual

Page 34

background image

Page   

iQ Series,

Ultrasonic Hand Held Systems User’s Manual

Dukane Manual Part No. 403-577-01

3.

Advanced Settings

Continued

After Advanced Settings is selected, a warning screen
is displayed as shown in Figure 5-13.

Adjusting these settings may affect the operation of
your unit. Before you change a setting, please check
with Dukane personnel for their recommendations.

The warning screen is shown for a few seconds, then,
the Advanced Settings screen appears.

See Figure 5-14.

Adjustments can be made to:

Free Run Frequency

;

Ramp Up Time

;

Frequency Lock and Hold

; and,

Trig-

ger By Power

, but note that Trigger by Power is only

available when the weld mode is time or energy.

Free Run Frequency

Free run is the frequency at which the generator
drives the ultrasound ouput pulses until a valid
feedback signal is detected. Typically this value
should be below the operating frequency of the
probe.

Follow the on screen prompts to make setting

adjustments.

Ramp Up Time
This parameter increases the amplitude linearly in
the programmed time period at the start of the weld
from zero to the programmed amplitude level. This
brings the probe up to operating amplitude smoothly
preventing shock stress.

Follow the on screen prompts to make setting

adjustments.

Lock and Hold
For an explanation of Frequency Lock and Hold,
please refer to Application Note 505 found on our
website at:
http://www.dukane.com/us/DL_ApplData.asp

Follow the on screen prompts to make setting

adjustments.

Continued

NOTE

Trigger by Power is only avail-
able when the weld mode is
either Time or Energy.

Figure 5-13 Warning Screen

Warning

Modified settings

may affect operation

of this unit!

Figure 5-14 Advanced Settings Screen

Advanced Settings

>

Trigger By Power

ON

OFF

Press Enter To Accept

Press Cancel To Abort

Lock and Hold

ON

OFF

Ramp Up Time

Free Run Freq

19900Hz

150mS