Power cords, Hand probe connector – Dukane Ultrasonic Hand Held System iQ Series User Manual
Page 19
Page 13
Section 3 – Installation
Dukane Manual Part No. 403-577-01
Power Cords
200/240 Volt Systems
The IEC AC power inlet connector mounted on the rear
panel requires a properly configured IEC compliant power
cord.
The 200/240 AC power cords supplied with the
generators are matched to the ultrasonic output power
rating and the continent of specified use. See Table 3-I.
Table 3- I
Standard IEC AC Power Cord Part Numbers
100/120 Volt Systems
(North America or Japan)
The power cord (including strain relief) supplied with the
100/120 AC systems is permanently attached to the rear
of the generator. Units with this power cord are for use in
North America or Japan.
HAND PROBE Connector
Ultrasound Output
The ultrasound output connector used with this generator
is integrated into a D-Sub style connector. This connector
provides superior shielding of electrical noise. The output
connector mates with a fully shielded ultrasound cable
that is secured to the generator with two simple, reliable
thumbscrews.
The ultrasonic output from this connector (that drives the
attached ultrasonic load) is a very high AC voltage. At
high power levels there is high current, and the cable must
be securely attached to the hand probe for safe operation.
Only use original equipment ultrasound cables for safe
and reliable system operation.
Continent of Use
Power Cord
Part Number
Power
North America
200 - 1541
240V, 10A
Europe
200 - 1542
240V, 10A
India
200 - 1624
240V, 10A