Lcd display overview, Manual weld, Operate – Dukane Ultrasonic Hand Held System iQ Series User Manual
Page 26
Page 0
iQ Series,
Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
LCD Display Overview
There are two basic kinds of screen displays:
Operate
screens, and
In Cycle
screens.
Figure 4-5 Example of an In Cycle Screen
IN CYCLE
Frequency: 40087 Hz
Power: 25 W
# 2
Status Indication
Stack Frequency
Power Draw
Power Bar Graph %
Figure 4-4 Example of an Operate Screen
Weld Mode -
Manual, Time, or
Energy
Manual Weld
Weld Time 0.500 S
Weld Energy 18 J
# 2
*
Data from
last weld
cycle.
Setup
number.
Asterisk indicates setup
is modified but not
stored in memory.
An Operate screen tells the operator
what happened in the last weld cycle.
An In Cycle screen activates when the probe activation
switch (trigger) is pressed.