beautypg.com

Navigating through the modes, Navigate to time mode, Manual weld – Dukane Ultrasonic Hand Held System iQ Series User Manual

Page 30: Weld by time

background image

Page  4 

iQ Series,

Ultrasonic Hand Held Systems User’s Manual

Dukane Manual Part No. 403-577-01

Navigating Through the Modes

When the generator is first powered up, the default
operating mode is Manual, and

Manual Weld

is shown

at the top of the display as shown in Figure 5-1.

Navigate to Time Mode

1. Follow the sequence shown in the figures to the right

to navigate from Manual mode to Time mode.

In Manual mode, press the TIME key (Figure 5-2).

2. The phrase, Enter Changes Mode, means when the

ENTER key is pressed, the mode will change. So
press the ENTER key, and the Weld by Time screen
seen in Figure 5-3 appears.

3. Set the time.

Use the and the keys to move the cursor
and to set the digits for the weld time you want.

4. Press the ENTER key to accept the time that has been

set (Figure 5-4).

Press the CANCEL key if you decide not to set the
time.

NOTE

Navigating to Manual Mode

Set Time or Energy (depending on mode) to
OFF, and press ENTER.
This will put you back in Manual mode.

Alternately:
Find an empty setup. Press SETUP.
Press ENTER.
A pop-up screen about defaults appears.

Select YES to load the default operating mode
which is Manual, and you can weld using the
Manual mode.

+ -

Manual Weld

Weld Time 0.000 S

Weld Energy 0 J

# 2

Figure 5-1 Manual Weld Mode

TIME key

Manual Weld

Weld By Time

OFF

Enter Changes Mode

ENTER key

Figure 5-2 Navigate to Time Mode

Weld by Time

Press Enter To Accept
Press Cancel To Abort

Weld By Time

OFF

S

Figure 5-3 Time Weld Mode - 1

Weld by Time

Press Enter To Accept
Press Cancel To Abort

Weld Time

0.500 S

Figure 5-4 Time Weld Mode - 2

ENTER key

Set the time.

Setup #1Empty
Load Defaults?

YES

NO