Connecting cables - quick start guide, Ac power inlet – Dukane Ultrasonic Hand Held System iQ Series User Manual

Page 18

background image

Page  1 

iQ Series,

Ultrasonic Hand Held Systems User’s Manual

Dukane Manual Part No. 403-577-01

Connecting Cables - Quick

Start Guide

Complete the basic connections as shown below:

AC Line Input

HAND PROBE Connector

Grounding Stud

AC Power Cord Connection

Step 1. Attach the female end of the power cord

(200/240V only) to the generator’s power inlet
connector -

A

in Figure 3-1.

(The 100/120V model’s power cord is permanently
attached to the unit.
)

Step 2. Attach the hand probe’s cable connector to the

generator’s HAND PROBE connection. -

B

in

Figure 3-1. Secure the connector to the system us-
ing the two jack screws attached to the connector
hood.

Step 3. Ground the generator chassis with a user–supplied

14-Gauge wire. Attach one end to the grounding
stud -

C

in Figure 3-1. Attach the other end to the

nearest grounded metal pipe or equal earth ground.

Step 4. Attach the male end of the power cord to a suit-

able line receptacle.

Optional Connections - See Page 14 for information

about the rear panel OUTPUTS connector.

NOTE

AC Power Inlet

Depending on your generator model, line
voltage required for the generator is either
100-120 VAC at 50/60 Hertz or
200-240 VAC at 50/60 Hertz.
The unit has a power switch, and is pow-
ered ON whenever the AC line power is
live and the switch is in the ON position as
shown in Figure 3-2 below.

Figure 3-1 Generator Detail - Rear Views

Figure 3-2

Rocker-style Power Switch/Circuit Breaker

Push ON

Push OFF

HAND PROBE

OUTPUTS

HAND PROBE

OUTPUTS

REAR VIEW

200/24O VOLT MODEL

REAR VIEW

100/12O VOLT MODEL

C

A

B

Power Cord Strain Relief

Optional

Connections

C