beautypg.com

Specifications, Installation options, Features – Avalon Firestyles Salish EF-2000 to 2001 User Manual

Page 7: Heating specifications, Dimensions: fuel, Electrical specifications

background image

Specifications

5

Travis Industries

9 3 5 0 8 1 2 2

1 4 1 1 0 0

Installation Options:

Freestanding Stove

Residential or Mobile Home

Horizontal or Vertical Vent

Features:

Ember Fyre ™ Burner for "Wood Fire" Look

Works During Power Outages

Optional Thermostat or Remote Control

Variable-Rate Heat Output

Blower Standard

Heating Specifications:

Approximate Heating Capacity (in square feet)*......1,200 to 2,000 With Blower, 800 to 1,600 Without

Maximum BTU Input Per Hour ...............................43,000 (NG & LP)

Minimum BTU Output on Low (with blowers on) .....23,384 (NG) 20,800 (LP)

Steady State Efficiency ............................................................................up to 78% (NG), 81% (LP)

AFUE......................................................................................................71% (NG), 73.7% (LP)

*

Heating capacity will vary depending on the home’s floor plan, degree of insulation, and the outside
temperature.

* *

Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent
of installed system. To measure the net BTU’s, multiply the BTU input by the efficiency percentage.

Dimensions:

Fuel:

This heater is shipped in
natural gas (NG)
configuration but may be
converted to propane (LP)
using the included LP
conversion kit. The sticker
on top of the gas control
valve will verify the correct
fuel.

8"

Weight: 240 Lbs

Measure

Clearances

from the

Stove Top

The starter section is 1/4"

above the top.

28"

33"

21-1/2"

Electrical Specifications

Electrical Rating .........................................................115 Volts, 0.8 Amps, 60 Hz (92 watts on high)

This manual is related to the following products: