Specifications, Installation options, Features – Avalon Firestyles Salish EF-2000 to 2001 User Manual
Page 7: Heating specifications, Dimensions: fuel, Electrical specifications
Specifications
5
Travis Industries
9 3 5 0 8 1 2 2
1 4 1 1 0 0
Installation Options:
•
Freestanding Stove
•
Residential or Mobile Home
•
Horizontal or Vertical Vent
Features:
•
Ember Fyre ™ Burner for "Wood Fire" Look
•
Works During Power Outages
•
Optional Thermostat or Remote Control
•
Variable-Rate Heat Output
•
Blower Standard
Heating Specifications:
Approximate Heating Capacity (in square feet)*......1,200 to 2,000 With Blower, 800 to 1,600 Without
Maximum BTU Input Per Hour ...............................43,000 (NG & LP)
Minimum BTU Output on Low (with blowers on) .....23,384 (NG) 20,800 (LP)
Steady State Efficiency ............................................................................up to 78% (NG), 81% (LP)
AFUE......................................................................................................71% (NG), 73.7% (LP)
*
Heating capacity will vary depending on the home’s floor plan, degree of insulation, and the outside
temperature.
* *
Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent
of installed system. To measure the net BTU’s, multiply the BTU input by the efficiency percentage.
Dimensions:
Fuel:
This heater is shipped in
natural gas (NG)
configuration but may be
converted to propane (LP)
using the included LP
conversion kit. The sticker
on top of the gas control
valve will verify the correct
fuel.
8"
Weight: 240 Lbs
Measure
Clearances
from the
Stove Top
The starter section is 1/4"
above the top.
28"
33"
21-1/2"
Electrical Specifications
Electrical Rating .........................................................115 Volts, 0.8 Amps, 60 Hz (92 watts on high)