Safety Label

Travis Industries

9 3 5 0 8 1 2 2

1 4 1 1 0 0

The listing label is shown below for your records. It can be found inside the right side panel.

L.P.

N.G.

L.P.

N.G.

Input Rate on “HI” (BTU/Hr) . . . . . . . 43,000

43,000

Minimum Inlet Pressure (inches W.C.) . . . . . . . . 11.5” 5.5”

Input Rate on “LO” (BTU/Hr) . . . . . . 26,000

29,600

Maximum Inlet Pressure (inches W.C.) . . . . . . . .

13”

7”

Manifold Pressure on “HI” (inches W.C.) . . . . . .

11”

3.5”

In USA, this appliance is equipped for installation from 0-2000 ft. (0-610 m). For altitudes above 2,000 feet, the vent
configuration, orifice, or combination of both may need to be changed. See owner’s manual for information on making
these changes.

FAN TYPE VENTED CIRCULATOR

Blower Electrical Rating: 115V., 1.5 Amps, 60 Hz, 150 Watts

Salish DVL Stove

Listed Vented

Gas Fireplace Heater

Tested and certified by OMNI-Test Laboratories, Inc. to the combustion performance and construction requirements of ANSI Z21.88b-1999, and
applicable sections of UL 307b.

The DVL FS is equipped from the factory only for use with Natural Gas. For conversion to LP (Propane) use kit supplied by the manufacturer. This
appliance must be installed in accordance with all local codes, if any; if not, in USA follow ANSI Z223.1-1992 and NFPA 54(88). Installation in
Manufactured or Mobile Homes must conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. This
appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless
a certified kit supplied by the manufacturer is used. See owner’s manual for information on making these changes. This appliance uses a millivolt-
type control system consisting of a gas control valve/regulator, a standing pilot burner assembly, a thermopile, a thermocouple, a piezo ignitor, and
the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 110 VOLT POWER TO OPERATE. All exhaust gases must be vented outside the structure of the
living-area. Combustion air is drawn from outside the living-area structure.

This appliance is a Vented Gas Fireplace Heater. Not for use with Solid Fuel.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information
manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide
(CO) poisoning and possible death.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by
a qualified service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present.
The control compartment, the burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.
This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation instructions.
This vented gas fireplace heater is not for use with air filters.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition.
Young children should be carefully supervised at all times when they are in the same room as the appliance.
CAUTION:Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
CAUTION:Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or
qualified service person.
Use direct vent systems listed in owner’s manual to vent this appliance to the exterior.

10850 117th Pl. N.E. Kirkland, WA 98033

Minimum Clearances to Combustibles

Unit to Sidewall ..................... 10” / 255mm

Alcove Min. Height ................

60” / 1520mm

Unit to Backwall .................... 4” / 100mm

Alcove Max. Depth.................

48” / 1220mm

Unit to Cornerwall ................. 4” / 100mm

Alcove Min Width...................

48” / 1220mm

Front of Unit........................... 36” / 910mm

Manufacture

2000

Jan.

Apr.

Jul.

Oct.

Date:

2001

Feb.

May

Aug.

Nov.

2002

Mar.

Jun.

Sep.

Dec.