Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting the pilot, the door must be opened (see
page 17).
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
Fireback (part # 98500754)
Follow the directions below to install the optional firebrick. Remove the log set prior to installation.
b
5/16" Nutdriver
Remove the two screws on
the back wall of the firebox.
Use these screws to secure
two fireback clips.
a
Remove the two screws on
the sides of the firebox and
the single screw on the
back wall.
Place the rear fireback on the clips
installed in step “a”. Secure the
fireback with the screw removed in
step “b”.
c
Place the side firebacks along
the sides of the firebox. Secure
with the fireback clips and the
screws removed in step “b”.
d