Features & specifications, Features, Installation options – Avalon Firestyles DVS Insert EF-2001 to 2005 User Manual
Page 6: Heating specifications

6
Features & Specifications
© Travis Industries
4041213
1 0 0 - 0 1 1 5 0
Features:
-
Works During Power Outages (millivolt system)
-
High Efficiency
-
Optional Thermostat or Remote Control
-
Ember Fyre™ for a "Wood Fire" Look
-
Quiet Blower for Effective Heat Distribution
-
Convenient Operating Controls
-
Variable-Rate Heat Output
-
Low Maintenance
Installation Options:
-
Residential or Mobile Home
-
Fireplace Insert
-
Masonry or Zero Clearance
(Metal) Fireplace
Heating Specifications:
Natural Gas
Propane
Approximate Heating Capacity (in square feet)*
500 to 1,500
500 to 1,500
BTU Input Per Hour on High
31,000
31,000
BTU Input Per Hour on Low
18,600
16,000
Efficiency** (with blowers on)
80 %
80.5 %
AFUE (Annual Fuel Utilization Efficiency)
71.3 %
71.8 %
*
Heating capacity will vary with floor plan, insulation, use of power heat vent, and outside temperature.
**
Efficiency rating is a product thermal efficiency rating determined under continuous operation
independent of installed system.
40-3/8"* 8x10 Panels
44-3/8"* 10x13 Panels
28-7/8"*
8x10
Panels
31-7/8"*
10x13
Panels
15-3/4"*
* Includes trim & standoffs
1-3/8"*
24-3/8"
16-3/8"
19-1/8"
See the section "Vent Requirements"
for vent location.
Face Sizing:
See the illustration on page 9.
Fuel:
This heater is designed either for natural gas or for propane. Check the sticker on top of
the gas control valve or check with the installer to verify gas use.
Compliance:
This unit has passed the ANSI Z21.88 – 1998, CSA 2.33 M98 Vented Gas Fireplace
Heater Standard as tested by OMNI-Test Laboratories, Inc. Beaverton, Oregon.
Electrical:
120 Volts, 1.3 Amps, 60 Hz (150 watts on high)