beautypg.com

Installation, Vent installation, Vent location – Avalon Firestyles DVS Insert EF-2001 to 2005 User Manual

Page 12: Vent configurations, For qualified installers only) © travis industries

background image

1 2

Installation

(for qualified installers only)

© Travis Industries

4041213

1 0 0 - 0 1 1 5 0

Vent
Installation

Inlet

Exhaust

Inlet

Exhaust

Termination

(Simpson

Part # 991)

DV Chimney

Liner Kit

(Simpson Part

# 923GK)

3” Gas

Liner

High-Temp.

Silicone

Apply high-temperature

silicone to the liners on

both ends and secure

with 2 screws.

Make sure to route the exhaust liner to the exhaust portion of the cap.

High-Temp.

Silicone

Vent Location

2-1/2"

(64 mm)

15-3/4"

(400 mm)

2-1/2"

(64 mm)

13-1/2"

(343 mm)

Center Line

13-1/4"

(337 mm)

Inlet (3” (75 mm) Dia.)

Exhaust (3” (75 mm) Dia.)

Fireplace

Opening

Vent
Configurations

Z.C. (Metal) firebox

Inlet & Exhaust Re-Line

Exhaust Only Re-Line

(recommended)

Direct Vent Cap

(part # 991)

Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.

3" Gas

Liner

Dura-Vent Termination Kit

(part # 923GK)

The block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.

Block-Off Plate
(non-combustible
materials)

NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.

Inlet

Exhaust

Inlet

Exhaust

Masonry Fireplace

Suggestion:
Paint the fireplace cavity
with latex paint to eliminate
the possibility of odors from
the fireplace circulating into
the room.

Any cracks or
damage inside the
chimney must be
repaired.