Caution, Safety label, Travis industries – Avalon Firestyles DVS Insert EF-2001 to 2005 User Manual
Page 29
Safety Label
2 9
© Travis Industries
4041213
1 0 0 - 0 1 1 5 0
The safety (listing) label is
on a plate chained to the
gas control valve. A copy
of the safety label is
shown to the right.
DVS Insert
Vented Gas Fireplace Heater
Tested to:
ANSI Z21.88b-1999 “V
ented Gas Fireplace Heater” and UL
307b-1995 “Gas Burning Heating
Appliances for Manufactured Hom
es”.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.
1/NFP
A
54.
Installation in Manufactured or Mobile Homes must conform with Manufactured Home Construction and Safety Standard, T
itle 24 CFR
,
Part 3280.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,
the optional
factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner
’s manual for details. This appli
ance is
not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s installation instructions.
Use only
approved coaxial direct vent system to vent this appliance to the exterior
. See owner
’s manual for approved brands of venting.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to th
e owner
’s
information manual provided with this appliance. For assistance or additional information consult a qualified installer
, servic
e agency or
the gas supplier
.
VENTED GAS FIREPLACE HEA
TER – NOT FOR USE WITH SOLID FUEL
CAUTION:
Hot while in operation. Do not touch. Severe burns may result.
Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away
.
Do not operate this appliance with glass removed, cracked or broken. Replacement of the
panel(s) should be done by a licensed or qualified service person.
Report No. 028-S-15b-5
Certified for USA
4800 Harbour Pointe Blvd. SW Mukilteo, W
A
98275
Minimum Clearances to Combustibles
Faceplate to Sidewall
..............
6”
Max 8” Deep Mantle Height
Above Faceplate
.........
10”
Front of Unit
.............................
36”
Side Facing to Faceplate
...........................................
6”
Top Facing to Faceplate
............................................
8”
Hearth Extension Front
.............................................
12”
Hearth Extension Sides
.............................................
0”
L.P
.
N.G.
L.P
.
N.G.
Input Rate on “HI” (BTU/Hr)*
. . . . . .
31,000
31,000
Minimum Inlet Pressure (inches W
.C.)
. . . . . . . .
11”
5.5”
Input Rate on “LO” (BTU/Hr)*
. . . . .
21,600
24,900
Maximum Inlet Pressure (inches W
.C.)
. . . . . . . .
13”
7”
Main Burner Orifice (DMS)*
. . . . . . .
.0625
#37
Manifold Pressure on “HI” (inches W
.C.)
. . . . . .
10”
3.5”
This room heater is equipped at the factory for use with natural gas. If conversion to propane (LP) fuel is desired the
optional factory conversion kit must be used.
Blower Electrical Rating:
115v
, 1.5
Amps, 60 Hz F
AN TYPE VENTED CIRCULA
T
OR
Manufacture
2004
Jan.
Apr
.
Jul.
Oct.
Date:
2005
Feb.
May
Aug.
Nov
.
2006
Mar
.
Jun.
Sep.
Dec.
(IGN) 0284