Installation, Insert clearances, Mantel clearances – Avalon Firestyles DVL Insert EF-2002 to 2005 User Manual
Page 9: Face sizing, For qualified installers only)

Installation
(for qualified installers only)
9
Travis Industries
4 0 4 1 0 2 8
1 0 0 - 0 1 1 5 1
Insert Clearances
•
Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture
and draperies.
Min. 6”
Side
Wall
Combustible or Non-Combustible Mantel
Min. 6”
Combustible Top Facing
Min. 8-1/2”
Side Facing
Min. 10”
12” Min. (from fireplace opening)
Max. 8”
See “Face
Sizing” Below
The non-combustible hearth
must be as wide as the face
and extend to both sides.
See “Face
Sizing” Below
Mantel Clearances
The mantel must be a minimum 10” above the face and a maximum 8” deep.
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Face Sizing
Lopi Discovery DVL
26”
35-3/4”
Avalon Rosario DVL
26”
35-3/4”
FPX Arched
FPX Artisan
NOTE: Artisan faces
vary in size.
26-1/2”
3-1/2"
34-3/4”
Access
Door
Radius = 45”
FPX 34
Rectangular
Bevel
Access
Door
26-1/2”
34-3/4”
Avalon
Cambridge
DVL
25-7/8”
36-3/4”
37-5/8”
2”
27-7/8”
33-5/8”
FPX 34
Architectural
Faces
Access
Door
36”
27-1/2”
* The decorative braces protrude 1/4”
2-3/8”
2-1/4”
27-1/2”
16-1/2”
Avalon
Craftsman
35-3/4”
27”
Avalon
Victorian DVL
Avalon
Rawhide
27”
35-3/4”