Caution, Safety label – Avalon Firestyles DVL Insert EF-2002 to 2005 User Manual
Page 30

3 0
Safety Label
Travis Industries
4 0 4 1 0 2 8
1 0 0 - 0 1 1 5 1
The safety (listing) label is on
a plate chained to the gas
control valve. A copy of the
safety label is shown to the
right.
DVL Insert
Vented Gas Fireplace Heater
Tested to:
ANSI Z21.88a-2000 “V
ented Gas Fireplace Heater” and UL
307b-1995 “Gas Burning Heating
Appliances for Manufactured Hom
es”.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.
1/NFP
A
54.
Installation in Manufactured or Mobile Homes must conform with Manufactured Home Construction and Safety Standard, T
itle 24 CFR
,
Part 3280.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,
the optional
factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner
’s manual for details. This appli
ance is
not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s installation instructions.
Use only
approved coaxial direct vent system to vent this appliance to the exterior
. See owner
’s manual for approved brands of venting.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to th
e owner
’s
information manual provided with this appliance. For assistance or additional information consult a qualified installer
, servic
e agency or
the gas supplier
.
VENTED GAS FIREPLACE HEA
TER – NOT FOR USE WITH SOLID FUEL
CAUTION:
Hot while in operation. Do not touch. Severe burns may result.
Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away
.
Do not operate this appliance with glass removed, cracked or broken. Replacement of the
panel(s) should be done by a licensed or qualified service person.
Report No. 028-S-21b-5
Certified for USA
4800 Harbour Pointe Blvd. SW Mukilteo, W
A
98275
Minimum Clearances to Combustibles
Faceplate to
Adjacent W
all
. . . . . . . . . . . . . .
6” (155mm)
Faceplate to Mantel (from top of insert face)
. . . . . . .
10”
(255mm)
Hearth Extension in Front
. . . . . . . . . . . . . . .
12” (305mm)
Faceplate to Front Facing
. . . . . . . . . . . . . . . . . .
. . . . .
8.5” (215mm)
Hearth Extension to Sides of Faceplate
. . . .
0” (0mm)
Flue V
ent
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . .
See Owner
’s Manual
FAN TYPE VENTED CIRCULA
TOR
Blower Electrical Rating: 1
15 V
., 1.5
Amps, 60 Hz, 150 watts
Steady State Efficiency
. . . . . . . . . . . .
Up to 81% (blowers on)
Output Capacity Rating
. . . . . . . . . . .
Up to 32,400 (blowers on)
L.P
.
N.G.
L.P
.
N.G.
Input Rate on “HI” (BTU/Hr)
.............
40,000
40,000
Minimum Inlet Pressure (inches W
.C.)
................
11
”
5.5”
Input Rate on “LO” (BTU/Hr)
...........
29,000
24,500
Maximum Inlet Pressure (inches W
.C.)
................
13”
7”
Main Burner Orifice (DMS)
...............
(2) 55
(2) 45
Manifold Pressure on “HI” (inches W
.C.)
............
10”
3.5”
This appliance is equipped for installation at 0-2000 ft.
In USA, for altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner
’s manual for information on making these changes.
Manufacture
2004
Jan.
Apr
.
Jul.
Oct.
Date:
2005
Feb.
May
Aug.
Nov
.
2006
Mar
.
Jun.
Sep.
Dec.
0446 (IGN)