7
© Travis Industries
100-01342
4150521
SAFETY NOTICE:
Please read this entire manual before you install and use your new room heater. Failure to
follow instructions may result in property damage, bodily injury, or even death. Contact
local building or fire officials about restrictions and installation inspection requirements in
your area.
Planning the Installation
We suggest that you have an authorized Travis Industries dealer install your fireplace insert. If you
install the fireplace insert yourself, your authorized dealer should review your installation plans.
Check with local building officials for any permits required for installation of this fireplace insert and
notify your insurance company before proceeding with installation.
The location of your wood heater in your home will decide how affectively the heat produced will spread
throughout your house. Attention to the home design with consideration of natural convection and air
circulation should be taken into account when choosing the placement of your heater within the home.
Preparation for Installation
Check for damage to the exterior of the fireplace insert (dents should be reported, scratches can be
fixed by applying touch-up paint).
Check the interior of the firebox (replace cracked firebrick and make sure baffle and combustor is in
place).
The fireplace insert can be lightened by removing the firebricks (pg. 38) - replace before operation.
Additional Accessories Needed for Installation
Face
Surround Panels (see page18 for sizing)
Packing List
Flue Attachment Gasket (with screws)
Bypass
Tool
GreenStart Igniter FireBrick and Igniter Housing (used with GreenStart igniters only)
Flue Alignment Tool
Brush for Combustor
Combustor Temperature Meter
Additional Requirements for Canada
Do not remove bricks or mortar from existing fireplace.
This fireplace insert must be installed with a continuous chimney liner of 6” diameter extending from
the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3
requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-Built
Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
Permanently seal any opening between the masonry of the fireplace and the facing masonry.
Fireplace insert, or surround panels, may be removed to inspect fireplace insert and fireplace.
Lock existing dampers in the open position.