Optional equipment 39, Greenstart, Igniter – firebrick and housing installation – Avalon Firestyles Small Flush Hybrid-Fyre User Manual
Page 39

Optional
Equipment
39
© Travis Industries
100-01342
4150521
GreenStart
TM
Igniter – Firebrick and Housing Installation
Minimum Fireplace Size
Igniter Firebrick and Housing
This insert is compatible with the GreenStart
TM
automatic wood-stove igniter. This optional component
uses a specialized firebrick and housing that are shipped with the insert. If you are using the igniter, install
these components as shown below. The igniter is installed as shown in the instructions included with the
igniter kit.
Igniter Firebrick
Igniter Housing
HINT: If you are not using the igniter, store these components inside the fireplace cavity in case the
homeowner later decides to install them.
1. Remove the two firebricks from the front left corner of the firebox.
2. Place the igniter firebrick as shown below.
Fireplace
5"
Igniter requires a minimum
fireplace width of 34.75"
(measured at a location 5" into
the fireplace opening).