Listing information 41, Do not remove this label, Olympic – Avalon Firestyles Olympic User Manual
Page 41: Freestanding installation

Listing
Information
41
© Travis Industries
93508061
4150520
Listing Label
DO NOT REMOVE THIS LABEL
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.
SUITABLE FOR USE IN CONVENTIONAL RESIDENTIAL INSTALLATIONS, MANUFACTURED HOMES AND ALCOVES.
MODEL:
OLYMPIC
Certified for USA and Canada
SERIAL NO:
Report No. B0499PRT-001
Control No. 4000515
CONFORMS TO: UL STD 1482; CERTIFIED TO ULC STD S627-2000, ULC STD S628-1993
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact your local building or fire officials
about restrictions and installation inspection in your area. Refer to local building codes and manufacturer’s instructions for precautions required for passing a
chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue
serving another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building
or fire officials.
FREESTANDING INSTALLATION
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black, with listed UL-103 HT factory-built chimney, suitable for
use with solid fuels or masonry chimney. Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required.
MANUFACTURED HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition, manufactured
home installations require outside air - use the optional pedestal or outside air boot.
● AMERI-TEC model DCC connector with model HS chimney
● DURA-VENT model DVL connector with DURA-PLUS chimney
● GSW-JAKES EVANS SUPERPIPE 2100
● I.C.C. EXCEL (103-HT) chimney with HP connector
● METALFAB model DW connector with TG chimney
● OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
● SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
● SELKIRK METALBESTOS model DS connector with model SSII chimney
● OLYMPIA VENTIS
®
with Ventis doublewall black stove pipe
A.
B.
C.
D.
E.
F.
G.
H.
16 in. / 407 mm
15 in. / 381 mm
9.5 in. / 242 mm
27.5 in. / 699 mm
17.5 in. / 445 mm
20.5 in. / 521 mm
US: 6 in.
(153 mm) / CAN: 8 in. (204 mm)
US: 16 in.
(407 mm) / CAN: 18 in. (458 mm)
16 in. / 407 mm
10 in. / 254 mm
7.5 in. / 191 mm
27 in. / 686 mm
12 in. / 305 mm
18 in. / 458 mm
US: 6 in.
(153 mm) / CAN: 8 in. (204 mm)
US: 16 in.
(407 mm) / CAN: 18 in. (458 mm)
Singlewall Connector
Conventional Residential
Installations
Minimum Clearances
To Combustibles And
Hearth Requirements:
Alcove, Manufactured Home and Reduced
Clearance Conventional Residential
Installations
FREESTANDING CLEARANCE DIAGRAM
ALCOVE SPECIFICATIONS
FLOOR PROTECTION DIAGRAM
STOVE
D
A
E
B
ST
OVE
45˚
F
C
SIDEW
A
LL
BACKWALL
ADJACENT WALL
ADJACENT W
A
LL
G
STOVE
G
G
H
FRONT
FLOOR PROTECTOR
Floor protection must be a non-combustible
material extending beneath the heater and to
the front, sides and back as indicated. See
Owner’s Manual for examples of non-com-
bustible materials that can be used.
Do not obstruct space beneath heater.
Max. Alcove Depth:
Min. Alcove Height:
Min. Alcove Width:
48 in.
See Owner’s Manual
See Owner’s Manual
FACTORY-BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACE INSTALLATION
INSERT
A
F
B
D
C
E
HEARTH EXTENSION
MANTEL
COMBUSTUBLE SIDEW
A
LL
COMBUSTIBLE F
ACING
NON-COMBUSTIBLE
FIREPLACE FACING
Minimum Clearance to
Combustibles and Hearth
Requirements
Standard
Model
Cook Top
Model
A.
B.
C.
With Shield
D.
With Shield
E. (US)
E.(Can)
F. (US)
F. (Can)
15 in. / 381 mm
13.5 in. / 343 mm
30 in. / 762 mm
17 in. / 432 mm
32 in. / 813 mm
19 in. / 483 mm
16 in. / 407 mm
18 in. / 458 mm
6 in. / 153 mm
8 in. / 204 mm
15 in. / 381 mm
13.5 in. / 343 mm
31 in. / 788 mm
18 in. / 458 mm
33 in. / 839 mm
20 in. / 508 mm
16 in. / 407 mm
18 in. / 458 mm
6.0 in. / 153 mm
8.0 in. / 204 mm
Factory-Built (Z.C.) Fireplace installations require a minimum 24” starter section directly connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.)
Fireplace chimney must have a minimum cross-sectional area of 28.85 square inches. The Factory-Built (Z.C.) Fireplace damper and control must be removed, or
secured in the open position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturer’s installation instructions. Factory-Built (Z.C.) Fireplace floor
protection must be 3/8” minimum non-combustible material or equivalent, extending 16” in front of insert and 8” to both sides. A metal deflector plate must be installed
if the flue collar is not completely behind the Lintel plate of the Factory-Built (Z.C.) Fireplace openings.
Electrical Rating:
Optional Blower:
115V., 60 Hz., 1.8 Amps
SKU # 99000138, 99000190
Replace glass only with 5mm neoceramic or
ceramic glass.
Do not route power cord under or in front of appliance.
TRAVIS INDUSTRIES, INC.
12521 Harbour Reach Drive
Mukilteo, WA 98275
Manufactured by:
www.travisproducts.com
Made in U.S.A.
2015
2016
2017
2018
Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
DATE OF MANUFACTURE
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020. 2.6 g/h, Method 28, 5H, 2015
0914