Minimum fireplace size, Fireplace insert installation, Fireplace requirements – Avalon Firestyles Olympic User Manual
Page 19: Leveling bolt installation
Fireplace
Insert
Installation
(for qualified installers only)
19
© Travis Industries
93508061
4150520
Fireplace Requirements
Figure 16 shows the minimum size requirements.
Figure 16
Leveling Bolt Installation
Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install, raise
the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the insert. Adjust
the bolts until they extend the same height as the hearth steps up. After the insert is installed, fine-tune
the leveling bolts to level the insert (see Figure 17).
Figure 17
a
c
e
f
22-1/4"
22-1/4"
29-3/8"
29-3/8"
11-5/8"
24-7/8"
45-3/8"
56-3/8"
52-1/4"
39-1/4"
54-1/4"
41-1/4"
Standard
Model
Cook-Top
Model
Minimum
Fireplace Size
a
b
c
d
e
f
g
h
i
j
Height (front)
Height (rear)
Width (front)
Width (rear)
Depth
Hearth Depth*
Hearth Width
Facing Width
Facing Height
with Mantel Shield
Mantel Height
with Mantel Shield
22-1/4"
22-1/4"
29-3/8"
29-3/8"
14-1/8"
22-3/8"
45-3/8"
56-3/8"
51-1/4"
38-1/4"
53-1/4"
40-1/4"
* This is the distance the insert protrudes from
the fireplace opening plus the required 16" of
hearth extension.
b
d
h
i
j
g
Non-Combustible Hearth
Combustible Mantel
Non-Combustible Facing
This distance is the
hearth step-up. The
leveling bolts should
stick out this far from the
base of the insert.
Fireplace
Hearth
The leveling bolts go
into the holes at the
rear corners of the