13.3. Project 3
This example describes a system where 4 Messengers XL’s were placed, serving the stales at
the left and right from the stage in a theatre and two for two upper balconies. The trick was to
radiate over the stage avoiding the stage microphones and arrive at the first seats. A second
set of Messengers XL was serving the first and the second balconies with the most remote
seat at 53 mt.
Stales units:
Data settings:
Messenger
: XL
Mounting height
: 3.17
Nearfield
: at 10 mt
Far field
: at 26 mt
Balcony
: no
Gain Lobe 1:
- 4 dB
Gain Lobe 2:
- 0 dB