Table 4-7, Connection state rdr, Table 4-8 – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual
Page 50: Domain connection sensor, Connection state sensor, Using hpi-b

Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
50
The shelf management resource contains the following two RDRs:
Domain management control
Read-only HPI control which allows the application to obtain the IP address, port, domain
name and other connection parameters of a particular shelf
Connection status sensor
Contains information about the current status of the connection to a shelf
The definitions of both HPI controls are given in the following.
4.4.3.2.1 Domain Management Control
This HPI control is only readable. It has the same structure and definition as the HPI controls
defined in
Table "Domain Management Control" on page 48
Table "Domain Management Control RDR" on page 48
.
4.4.3.2.2 Connection State Sensor
This HPI sensor represents the status of the connection to a shelf. When the connection is
interrupted, an HPI event of type SAHPI_ES_OFF_LINE is generated. When the connection is
reestablished, an HPI event of type SAHPI_ES_ON_LINE is generated. An application can access
a shelf only when the state of this sensor is SAHPI_ES_ON_LINE. The definition of this sensor is
given in the following tables.
Table 4-7 Connection State RDR
SaHpiRdrT
Value
RecordId
Assigned by HPI
RdrType
SAHPI_SENSOR_RDR
Entity
The same entity as domain management resource
RdrTypeUnion
MOTHPI_SENSOR_NAME_DOMAIN_CONNECTION
Table 4-8 Domain Connection Sensor
SaHpiSensorRecT
Value
Num
MOTHPI_SENSOR_NUM_DOMAIN_CONNECTION
Type
SAHPI_CHASSIS