beautypg.com

Maintenance, Resetting the temperature cutoff switch, Light bulb replacement – Dimplex BF8000ST User Manual

Page 11

background image

11

C. Interior Light Control
Turn the interior light control knob to increase or decrease the

brightness of the interior light.

D. Heater Thermostat Control
To adjust the temperature to your individual requirements, turn the

thermostat control clockwise all the way to turn on the heater. When

the room reaches the desired temperature, turn the thermostat knob

counter clockwise until you hear a click. Leave in this position to

maintain the room temperature at its setting. For additional heat, turn

clockwise until you hear the click again and the heater will turn on. To

turn the heater off, rotate the knob fully counter clockwise.

E. Main On/Off Switch
The Main On/Off Switch supplies power to all fireplace functions.

Resetting the Temperature Cutoff Switch

This unit is equipped with a thermostat which controls the temperature

of the room by turning the heater on and off. The heater is protected

with a safety device to prevent overheating. Should the heater

overheat, an automatic cut out will turn the heater off and it will not

come back on without being reset. It can be reset by switching the

Main On/Off Switch to off and waiting five (5) minutes before switching

the unit back on.

CAUTION: If you need to continuously reset the heater, unplug the

unit and call Technical Support at 1-888-346-7539. Please have

your model and serial number ready when calling.

Maintenance

WARNING: Disconnect power before attempting any maintenance

or cleaning to reduce the risk of fire, electric shock or damage to

persons.

Light Bulb Replacement

Allow at least five (5) minutes for the light bulbs to cool before touching

them to avoid accidental burning of the skin. The light bulbs need