Advanced Calibration

Advanced Calibration uses 4, 9, 16 or 25

points to effectively calibrate touch panel

linearity of aged touch screens. Click this

button and touch the red squares in

sequence with a stylus. To skip, press
ESC’.

Command Calibration

Command call calibration function. Use

command mode call calibration function,

this can uses Standard, 4, 9, 16 or 25

points to calibrate E.g. Please run ms-dos

prompt or command prompt c:\Program

Files\PenMount Universa Driver\Dmcctrl.exe

-calibration 0 ( Standard Calibration)

Dmcctrl.exe - calibration ($) 0= Standard

Calibration 4=Advanced Calibration 4

9=Advanced Calibration 9 16=Advanced

Calibration 16 25=Advanced Calibration 25


1. Please select a device then click “Configure”. You can also double click the device too.

2.Click “Standard Calibration” to start calibration procedure