Aervoe 500-Watt Battery Pack User Manual
Page 8
8
OPERATING INSTRUCTIONS
Once charged, the Energy Center is ready to use. All power outputs may be used simultaneously as
long as the total power draw of all devices plugged in does not exceed the maximum power rating of
the installed batteries. For optimum battery life avoid draining the batteries below 1 bar on the Battery
Meter. If possible, recharge before capacity drops that low and the unit shuts down.
System On and Off
1.
Turn the MAIN POWER KEY clockwise to ON.
2.
Turn the AC or DC POWER SWITCH to ON depending on the devices you will be operating.
3.
The MAIN BATTERY METER should illuminate and indicate the status of the internal 500W
battery. If auxiliary #9691 Battery Packs are installed, the AUX BATTERY #1 & #2 METERS will
also illuminate.
4.
To shut the system off when not in use including long-term storage, turn all POWER SWITCHES
OFF, and turn OFF the MAIN POWER KEY and remove it from the Energy Center.
5.
Disconnect all devices.
120V AC Power Operation (Pure Sine Wave Inverter)
Pure Sine Wave Inverter Information: Pure sine wave power is suitable for most AC devices and
power supplies used in electronic equipment, transformers, and motors. Aervoe assumes no liability
if used with medical equipment or life support systems. The 120V AC Outlets cannot be used while
charging. Any attempt to do so will cause the system to safely shut down.
CAUTION: The 120V AC operation can safely power common AC appliances and devices based
on the listed power specifications. Verify that the device you wish to operate does not exceed the
specifications to prevent inverter overload or damage to the Energy Center or your device.
POWER SPECIFICATIONS
#9690 Energy Center
(500Wh capacity)
max. 400W load
#9690 Energy Center + 1 #9691 Battery Pack
(1000Wh capacity)
max. 800W load
#9690 Energy Center + 2 #9691 Battery Packs
(1500Wh capacity)
max. 1200W load
1.
Turn the MAIN POWER KEY and AC POWER SWITCH on.
2.
Plug in your 120V AC device to either of the 120V AC OUTPUTS and operate as normal.
3.
Disconnect the device when not in use.
DC Power Operation
The DC power operation includes a DC POWER SWITCH that when switched on provides power to
the USB ports and the 12V DC sockets. NOTE: These outputs cannot be used during charging. Any
attempt to do so will cause the system to safely shut down.
12V DC Output
The 12V DC operation can operate 12V devices rated at 15A (180W) per outlet. Do not operate
devices higher than 15A. Overload and short-circuit protection fuses are located next to each
12V DC receptacle. If these need to be replaced, make sure the DC POWER SWITCH and MAIN
POWER KEY are off. Replace with the specified fuse.
1.
Turn the MAIN POWER KEY and DC POWER SWITCH on.
2.
Plug in your 12V DC device (15A OR LESS) to either of the 12V DC OUTPUTS and operate
as normal.
3.
Disconnect the device and turn off the DC POWER SWITCH when not in use.