32 Multi Format LCD Monitor

Multi Format LCD Monitor 33

SWM-170A

SWM-170A

SWM-170A

SWM-170A

SDI A

SDI A

SDI A

SDI A

[1] Firmware Upgrade

[2] Color Calibration

6. Firmware Upgrade & Color Calibration

The USB portable storage device (Thumb

drive) is needed for Firmware Upgrade.

Select the PAGE III of [SYSTEM] menu to

activate.

1. Connect the USB to the USB Slot on the

front of the monitor.

2. Set the [S/W UPGRADE] as [ON].

3. Search the USB.

4. The [S/W UPGRADE START] activates when

the USB connection is completed.

The Color Probe is need for Color

Calibration.

Available Color Probe : K-10, Eyeone

Display Pro and Specbos 1211.

Select the PAGE III of [SYSTEM] menu to

activate.

1. Connect the Color Probe to the USB Slot on

the front of the monitor.

2. Set the [DEVICE] as the Color Probe which

will be connected.

3. Set the [Color Calibration] as [On].

4. Then the USB Color Probe is searched

automatically.

5. The [Color Calibration] activates when the

USB connection is completed.

5. Select the [S/W UPGRADE START] to start

the firmware update.

* While the Upgrade is conducting, the

monitor screen turns off and the monitor

stops functioning.
* When the Upgrade is completed, the

monitor reboots.
* The Upgrade process takes about 30

minutes according to the Firmware type.

- During the Upgrade, do not turn off or

control the product.

- Before the Upgrade, a message is indicated

as below for 5 seconds.

* The firmware update may tak 30 minutes.

Please do not turn off the monitor while

updating.

6. Set the value of [TARGET LUMINANCE], [K-10

CHANNEL] and [COLORSPACE].

7. Select the [CALIBRATION START] to start the

calibration.

* After the calibration starts, various patterns

come on the screen and conduct the color

calibration.
* The Color Calibration takes about 10~20

minutes.

1080/60i

1080/60i

1080/60i

1080/60i

PAGE VI >> PAGE V

COPY DATA

CAL. LOG COPY START

S/W UPGRADE

S/W UPGRADE START

PAGE III >> PAGE VI

DEVICE

COLOR CALIBRATION

TARGET LUMINANCE

K-10 CHANNEL 00:

COLORSPACE

CALIBRATION START

MEASUREMENT

PAGE III >> PAGE VI

DEVICE

COLOR CALIBRATION

TARGET LUMINANCE

K-10 CHANNEL 00:

COLORSPACE

CALIBRATION START

MEASUREMENT

PAGE VI >> PAGE V

COPY DATA

CAL. LOG COPY START

S/W UPGRADE

S/W UPGRADE START

OFF

OFF

K-10

OFF

80cd/m

2

REC-709

Y:000.00 x:0.000 y:0.000

K-10

ON

80cd/m

2

REC-709

Y:000.00 x:0.000 y:0.000

OFF

ON

7. Button Functions

This product is capable of processing

various input signals.

The signal input settings are as follows.

1. Press the MENU button on the back of

the product for more than 1.5 seconds and

activate the menu below.

2. Press the MENU button to activate the OSD

menu.

When the FUNCTION button is set to

ASPECT

1. Four different aspect modes are available.

When the input signal is SDI -A/B,

Composite 1/2/3 or S-Video and the input

signal format is SD :

1) 4:3 mode : Cuts the sides of the original

image to fit to 4:3 aspect ratio.

2) 16:9 mode : Stretches the image in “1) 4:3

mode” to fit to 16:9 aspect ratio.

3) 4:3 Ex mode(Extend) : Extends the image

vertically without altering the source image.

4) 16:9 Ex mode(Extend) : Stretches the

image in “3) 4:3 mode(extend)” to fit to 16:9

aspect ratio.

* NTSC and PAL signals are known to be 4:3

aspect ratio signals, but their aspect ratio

is not exactly 4:3. Therefore, select “1) 4:3

mode) to display the exact 4:3 aspect ratio,

select “3) 4:3 mode (extend)” to display the

image without altering the source image.

* ASPECT button lamp status: 1 - 1)/3) Off, 2 -

2)/4) : On.

2. When the input signal is DVI DIGITAL or

HDMI mode, all “1 – 1),2),3),4)” display the

image in 4:3 and 16:9 without altering the

source image.

3. For the above 1), 2) aspect modes, ZERO

SCAN is the standard scan mode. And, in the

other scan modes, aspect ratio changes

using the image in its selected scan mode.

Used to make a quick setting of the

Function Key. Select the PAGE III of

[SYSTEM] menu to activate.

When the FUNCTION button is set to

SCAN

1. Press the FUNCTION button continuously to

activate various scan modes.

ZERO SCAN -> UNDER SCAN -> 1:1 SCAN ->

USER ASPECT -> OVER SCAN

2. When the SCAN mode is 1:1 SCAN, Press the

ENTER button to rotate the position.

1. When the OSD menu is activated, this

button is used to confirm a chosen value (or

mode).

2. May also be used to control the Bright/

Contrast/Chroma/Aperture value during the

OSD menu inactivation.

3. Use the UP/DOWN buttons to adjust the

value when the desired function is selected.

[1] MENU Button

[2] Function key set

(F1/DOWN) (F2/UP)

[3] ENTER Button

SDI-A

SDI-B

DVI-DIGITAL

HDMI

OPTIC

NO VIDEO