Hardened PoE Ethernet Switch

17

Alarms for Power and Port Link Failure

Step 1: There are two pins on the terminal block are used for power failure

detection. It provides the normally closed output when the power
source is active. Use this as a dry contact application to send a
signal for power failure detection.

Power Input Assignment

48VDC

Power2

Power
Ground

48VDC

Power1

Power
Ground

Earth
Ground

Terminal
Block

Relay Alarm Assignment

FAULT

*Relay warning signal disable for
following:
The relay contact closes if Power1
and Power2 are both failed but
Power3 on.
The relay contact closes if Power3
is failed but Power1 and Power2
are both on.


Special note:
The relay output is normal open position when there is no power to the
switch. Please do not connect any power source to this terminal to
prevent the shortage to your power supply.