Paxton Superchargers Dodge Viper User Manual
Page 27

9-3
P/N: 4809643
©2004 Paxton Automotive
All Rights Reserved, Intl. Copr. Secured
12APR04 v1.1 01-03Viper(4809643v1.1)
5.
The supplied yellow wire will be used
as the “trigger” wire and should be con-
nected to terminal #85 using a slide
connector. The other end of the wire
will be connected in section 11.
6.
Run the black wire from terminal #86
on the water pump relay to the
“ground” located beneath the power
brake booster or any other good ground
location.
7.
Connect the fuse holder using a yellow
slide connector to terminal #30 on the
aftercooler pump relay and to the fuse
box power terminal on the front of the
fuse box using the supplied yellow ring
terminal connector.
8.
Use the supplied black wire, ring termi-
5.
Attach the water cooler to the installed
bracket and tighten so that the water
cooler is as far to the passenger’s side
as possible.
***CAUTION***
In the following step, use extreme care when drilling
through the oil cooler flange. If the drill bit slips or
goes through the hole too far, it will damage the radia-
tor, oil cooler or the AC condenser.
6.
Use the unfastened bracket to serve as a
template to drill a 5/16" hole in the top
flange of the oil cooler. Install the sup-
plied 5/16" hardware and tighten.
7.
Connect the outlet of the water pump to
the far side of the water cooler with the
installed 3/4" hose trimmed to fit.
Clamp each end. (See Fig. 9-h.)
4.
Using supplied hardware, loosely attach
one of the supplied brackets to the pas-
senger’s side oil cooler mounting bolt.
(See Fig. 9-g.) Attach the other sup-
plied bracket to the supplied water
cooler using the supplied 1/4" hard-
ware.
Fig. 9-e
Fig. 9-f
Fig. 9-g
WATER
PUMP RELAY
PCM COVER
(WILL BE REMOVED LATER)
nal and slide connectors to extend the
water pump ground wire (brown wire
on Hella pump) to the same grounding
location used for the water pump relay.
9.
Route the red wire from the water
pump to relay terminal #87. Using the
supplied butt connector, attach the red
wire to the positive wire on the water
pump (green wire on the Hella pump).
10. Install the supplied plastic wire loom
around the water pump power wires
and secure.
***NOTE***
Double check that all wires are connected to the proper
relay lugs.
D.
Water Cooler Installation
1.
Using sealant, insert the 90° fittings in
the inlet and outlet of the water cooler
and point them towards each other.
2.
Drill the air duct directly underneath
the bumper using a 1-1/8" hole saw on
both sides. Additionally, on the passen-
ger’s side, drill another hole next to the
radiator overflow tank so that the hose
can be routed smoothly from the CAC
to the water cooler.
3.
Loop the supplied hose through each
hole and connect to the water cooler.
Install and tighten a supplied plastic
clamp on each hose connection. (See
Fig. 9-f.)
CLEARANCE BUMPER
AS NECESSARY