Power consumption management – NEXCOM NIFE 100 User Manual
Page 77
Copyright © 2015 NEXCOM International Co., Ltd. All Rights Reserved.
63
NIFE 100/101 User Manual
Appendix A: Power Consumption
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of system, and the loading of power supply.
Test Equipment
PROVA CM-07 AC/DC CLAMP METER
Device Under Test
DUT: sys#1/
Test Procedure
1. Power up the DUT, boot into Windows 8 x32 Pro.
2. Entering standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.
Test Data
Sys #1
Sys #1
+12V
+24V
Full-Loading Mode
2.03A
1.11A
Total
24.36W
26.64W
Standby S3 Mode
0.93A
0.49A
Total
11.16W
11.76W